• Medical > Blood Glucose Meter > LS-9
  • LS-9
    Blood Glucose Meter
    Enquire now
  • The WISU No Coding Required Series Blood Glucose Meter is designed as a total healthcare solution. It is easy to operate and to carry on-the-go to get on with your daily life. Large LCD screen, simple interface, and automatic strip type detection make this product ideally designed for healthcare needs for a variety of users.
  • Features

    • No coding

    • Accuracy & Precision

    • Small sample size 0.6μL

    • 1000 Memories

    • Ketone Warning

    • Before/After Meals

    • 4 Daily Alarms Reminders

    • Large LCD Display

    • Result in 5 seconds

    • Test function: Blood Glucose

    The WISU No Coding Required Series Blood Glucose Meter is designed as a total healthcare solution. It is easy to operate and to carry on-the-go to get on with your daily life. large LCD screen, simple interface, and automatic strip type detection make this product ideally designed for healthcare needs for a variety of users.

    Test Function Blood Glucose
    Measuring Range 10 ~ 750 mg/dL (0.6 ~ 41.7 mmol/L)
    Calibration Plasma qruivalent
    Test Time 5 seconds
    Memory Capacity 1000 test results
    Operation Temperature/ Humidity 50 - 104 °F (10 - 40 °C), 20 ~ 80 % humidity
    Storage Temperature/ Humidity -4 ~ 122 °F (-20 ~ 50 °C), < 80 % humidity
    Sample Volume 0.6 μl
    Sample Type Capillary whole blood and venous blood
    Hematocrit Range 20 - 60 %
    Power Supply One CR2032 Batteries (3V)
    Battery Life More than 1000 times
    Dimensions 90 x 48 x 15 mm
    Weight 50 grams (including battery)
    Display LCD display
    Daily Alarm Function 4 sets
    Test Method Glucose Dehydrogenase (GDH) biosensor
    Automatic Power Off 1 minute after last action



    1. LS-9 Blood Glucose Monitoring Meter
    2. LS-9 Blood Glucose Test Strip (10 test strips/vial)
    3. Instructions for Use
    4. Battery (CR2032 lithium coin cell)
    5. Lancing Device (Puncturer)
    6. Lancets (10 pcs/pack)
    7. Carrying Case
    8. Lancing Device Instruction
    9. Test Strip Instruction

    For safety and to prevent cross-contamination, always place the protective cover back on before discarding the used lancets. To avoid injury, do not leave a used lancet in the puncturer. Always remove used lancets immediately after a test.

    • Unscrew the puncturer’s adjustable tip.

    • Insert a lancet into the carrier.

    • Twist off the protective cover to expose the lancet tip.

    • Replace the adjustable tip tightly.

    • Choose a desired skin penetration depth by rotating the top portion of the adjustable tip until the appropriate setting number lines up with the arrow. Settings are based on skin type:
    - Depth 1~2 for soft or thin skin
    - Depth 3 for average skin
    - Depth 4~5 for thick or calloused skin

    • Hold the tip of the puncturer with one hand and pull the sliding mechanism back with the other. When you hear a click, the trigger rises up.

    • Release the sliding mechanism. The puncturer is now ready to obtain a blood sample.

    Our LS-9 Blood Glucose Meter offer a limited two (2) year warranty.

    This warranty does not extend to failures resulting from accident, misuse, abuse, alteration, use of unauthorized service, parts or cleaning solutions, or failure to comply with Instruction Manual.

    Related Items

    Enquire now

    Blood Pressure Monitor


    Pulse Oximeter